Normal installation – right-angled
Distance to furniture (min.) in mm
Minimum distance to fire walls.
Section of fire wall to the side
Section of fire wall in front
*
where dimensions are not specified, follow the national/local provisions.
Without side glass with Non-in-
sulated flue. Minimum distance
to combustible material
Nexo 1025 (uden sideglas)
350
570
Without side glass with Non-in-
sulated flue. Minimum distance
to fire wall
Nexo 1025 (uden sideglas)
Nexo 1025 (uden sideglas)
150
50
370
17
341
Nexo 1025/1225 afstande til brændbart UISOLERET røgrør
Nexo 1025/1225 afstande til brændbart UISOLERET røgrør NORSK BRANDMUR
50
attika
RAIS/
– User manual for Nexo
Nexo
Non-insulated flue
900
50
400
Without side glass with insu-
lated flue. Minimum distance
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
to combustible material
450
350
670
570
Nexo 1025/1225 afstande til brændbart I
Without side glass with insu-
lated flue. Minimum distance
to fire wall
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
Nexo 1025 (uden sideglas)
Nexo 1025 (med sideglas)
50
250
200
150
341
491
470
370
Nexo
insulated flue
900
50
400
Nexo 1025/1225 afstande til bræ
50
450