1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Cold water (heat source)
3.2
Temperature spread of heating waterat W10 / W35
3.3
Heat output / COP
3.4
Heating water flow with an internal pressure differential of m³/h / Pa
3.5
Cold water flow rate at an internal pressure differential of
(heat source)
3.6
Refrigerant; total filling weight
3.7
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current W10 W35 / cos ϕ
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. W10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump controller must always be ready for operation.
EN-10
°C
° C
K
1
at W7 / W55
kW / ---
1
at W10 / W50
kW / ---
1
at W10 / W45
kW / ---
1
at W10 / W35
kW / ---
m³/h / Pa
type / kg
type / litres
2
H x W x L mm
Inch
Inch
kg
V / A
1
W10 W35
kW
A
A / ---
4
WI 9ME
IP 20
Indoors
EN 255
EN 14511
Up to 55
+7 to +25
9.5
5.0
6.9 / 2.5
7.7 / 3.2
7.7/ 3.7
8.3 / 5.1
8.2 / 4.8
0.75 / 7000
1.4 / 24000
2.0 / 6200
R407C / 1.7
Polyolester (POE) / 1.0
1445 x 650 x 575
G 1¼" external
G 1¼" external
156
230 / 16
1.62
1.69
26
0.8
9.18
3
Yes
1
Internal
WI 14ME
IP 20
Indoors
EN 255
EN 14511
Up to 55
+7 to +25
8.8
5.0
12.2 / 2.3
13.4 / 3.4
13.4 / 3.8
13.6 / 5.0
13.5 / 4.7
1.3 / 7000
2.3 / 22000
3.3 / 19000
R407C / 1.9
FV68S / 1.7
1445 x 650 x 575
G 1¼" external
G 1¼" external
165
230 / 25
2.72
2.87
45
14.8
16.6
3
Yes
1
Internal