3. Installation

3.1 Selecting Mounting Location

 Do not mount the inverter on flammable construction materials.
 Mount on a solid surface.
 IMEON may possibly be noisy during operation which would be uncomfortable if installed in a
living room area.
 The temperature may cause a reduction of power due to the excessive heating.
 Install the IMEON at eye level in order to allow the LCD display to be read at all times.
 Dusty conditions may impair the performance of this inverter.
 Install the inverter in a protected place, free from foreign bodies (dust, insect, ...), free from
corrosive air (salt, ammonia, ...), where the air circulates easily.
FR
 Do not switch IMEON on, if the temperature or the humidity are out of the authorized limits.
FR
The ambient temperature should be between -20°C and +50°C and relative humidity should
EN
be between 0% and 90% to ensure optimal operation.
 For proper air circulation to dissipate heat, allow a clearance of approx. 50 cm to the side and
ES
approx. 50 cm above and below the IMEON.
IT
 For proper operation of this inverter, please use appropriate cables for grid connection.
 For the appropriate functioning of this inverter, please use adapted cables cross- section (taking
into account the length of cables, the mode of installation, the impedances, currents and voltage).
 The recommended installation position (vertical) is to be adhered to.
 Installation must be adapted to the weight and the dimensions of the inverter.
 This inverter is designed with IP20 for indoor applications only.

3.2 Material provided

The inverter box contains :
1 inverter IMEON 3.6
1 Smart Meter + 1 clamp
1 pair of MC4 connectors
1 connector « Grid connection »
1 connector « AC BACKUP »
1 battery connector and 2 terminals
1 installationmanuelle
1 Wi-Fi antenna
1 relay
2 screws of wallmounting

3.2.1 Recommended equipment

This section does not specify the necessary protective equipment for the installation and for the
operator himself (electrical, thermal ...). The qualification of the worker and the protective equipment
must comply with the applicable standards and regulations.
56
IMEON INVERTER
IMEON 3.6
IMEON_installation_guide_rev.D.5
IMEON 9.12
Un inverter IMEON 9.12
1 Smart Meter
1 pairs of MC4 connectors
1 connector « Grid connection »
1 connector « AC BACKUP »
1 battery connector and 2 terminals
1 instalationmanual
1 Wi-Fi antenna
1 relay
2 screws of wallmounting

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

9.12

Table des Matières