In order to avoid the above, we would recommend using the guidelines as set out below:
- set temperature to between 70 and 75
- set the circulation pump thermostat to 55
setting the thermostat at this level will allow the installation to heat up faster.
The water temperature difference between the desired working temperature, and the return water
temperature should not differ by more than 20
less than 50
c. That the wood moisture content is no more than 20%. This is related to the dew point
o
temperature (release of water vapour from the timber) of 48
The preferred fuel is seasoned wood e.g. beech, birch with a moisture content of no more than 20%.
Regular cleaning of the combustion chamber/Firebox and exhaust duct is recommended, especially
if there is a noticeable carbon build up.
10. Graphic connection diagram
CONNECTION DIAGRAM FIREPLACE WITH WATER JACKET IN OPEN SYSTEM
22
c,
o
c.
o
c and also that the return water temperature be not
o
o
c. proper combustion of fuel is essential.
1. Fireplace insert with water jacket
2. exhaust outlet
3. electric controlled air inlet
4. open expansion vassel
5. automatic water suplement (of aqueduct)
6. The pump
7. control unit msk glass
8. supply from the aqueduct
9. distributor c.o.
10. Heat receiver c.o.
11. safety tube 25 mm inside.
12. expansion pipe 25 mm inside.
13. drain pipe to sewer.
14. overflow to sewer pipe.
15. Water circulation output
16. coil pipe output
17. Thermal sensor output valve.
18. outlet temperature sensor for msk Glass