Installation
NOTICE
Risk of damage due to lubri-
cants
Seals may be destroyed by greasing
agents or oil.
f Do not use any greasing agents or
oil for the installation.
f Flush any dirt particles or grease or
oil residues out of the pipework.
f Consider the latest technical status
(e.g. VDI 2035), when choosing the
operating fluid.
1
2
3
4
5
6
7
Illust. 6: Installation cross section
(1)
Block or stud wall
(2)
"Unibox T"
(3)
Plaster
(4)
Pipe conduit unit (separate accessory)
(5)
Edge insulating strip (separate acces-
sory)
(6)
Screed
(7)
Protective tube (separate accessory)
24

6.2 Installation of the "Unibox T"

Install the "Unibox T" has to be
chosen so that the heating fluid
passes first through the surface
heating circuit and then through the
valve of the "Unibox T".
5
4
Illust. 7: Connection
(1)
Flow distributor/return collector
(2)
"Unibox T"
(3)
Surface heating circuit
(4)
Supply
(5)
Return
1. Provide a connection at the flow distributor.
2. Lay the surface heating circuit.
Lay the heating circuit in a spiral
pattern to achieve an even heat
distribution.
3. Remove the protection cover of the "Uni-
box T" (you must refit the protection cover
after commissioning) and place the "Uni-
box T" into the wall at the desired location.
Unibox T
1
2
3
102272280-V01.02.2020