Electrical connection
The installed electric motor is connected and ready for operation. The connec
tion complies with the applicable VDE and DIN regulations.
The mains connections provided by the client as well as the used extension
cable must comply with these regulations.
Damaged electrical connection cables
Insulation damage often occurs on electrical connection cables.
Reasons are:
•
Pressure, if the connection cable is drawn through windows or doors.
•
Kinks due to improper fixing or drawing of the connection cable.
•
Cuts due to running over the connection cable.
•
Insulation damage due to pulling out of the mains socket.
•
Ruptures due to aging of the insulation.
Such damaged electrical connection cables must not be used and are a dan-
ger to life due to their insulation damage.
Check electrical connection cables regularly for such damage. Make sure that
the connection cable is not live when checking.
Electrical connection cables must comply with the applicable VDE and DIN
regulations. Only use connection cables with the label H 07 RN.
A label on the connection cable indicating the type is stipulated.
Alternating current motor
•
The mains voltage must be 230 volts 50 Hz.
•
Extension cables must have a crosssection of 1.5 mm
25 m, and at least 2.5mm
•
The connection to the mains must be protected with a 16 A slowacting
fuse.
Important notes!
The electric 230 V/50 Hz motor is designed for
operating mode S6/30%.
If overloaded, the motor switches off automati
cally. After a coolingdown period (varies in
time), the motor can be switched on again.
for a length of 25 m and more.
2
Electrical connection
up to a length of
2