Cleaning:
• Clean the motor cover and the machine and vacuum up the dust.
Motor
• The mains cable should be replaced immediately if pulled out, cut or dama­
ged in any other way.
• Do not lubricate the motor bearings or internal parts!
Saw arm bearings
Lubricate the saw arm bearings every 50 hours. Proceed as follows (Fig. 12).
• Turn the saw to the side
• Apply a generous amount of SAE 20 oil to the shaft end and bronze bea­
rings.
• Let the lubricant oil work in overnight.
• Repeat the procedure the next day on the other side of the saw.
Repair:
This product does not contain any parts that can be repaired by the consu­
mer. Contact a qualified specialist to have it checked and repaired.
Storage:
Store the device and its accessories in a dark,
dry and frost­proof place that is inaccessible
to children. The optimum storage temperature
is between 5 and 30˚C. Store the electrical
tool in its original packaging.
36
CAUTION:
Do not clean plastic parts with aggressive
agents. A mild rinsing agent on a wet cloth
is recommended. The machine must not
get in contact with water.
WARNING!
Only perform repairs and maintenance work according to these
instruction! All further works must be performed by a specialist.
Only use OEM parts for maintenance work. Using parts other than
original parts can cause damage to the machine.