Product Dimensions

30" Model
16
"
/
1
2
(42 cm)
11
/
"
1
2
(29.2 cm)
2
/
"
3
8
(6 cm)
A
26"
29
/
"
15
16
(66 cm)
(76 cm)
A. 30" Cabinet inner dimensions
MIN: 27
15
MAX: 28

Cabinet Dimensions

C
E
F
A. 12" (30.5 cm) min. upper
cabinet height
B. 30" cabinet width:
min. 27.4" max 28.5"
36" cabinet width:
min. 33.9" max 34.5"
C. 24" (61.0 cm) min. from electric
cooking surface, 27" (68.6 cm)
min. from gas cooking surface,
36" (91.4 cm) suggested max.
bottom of cabinet to cooking
surface
6"
(15.2 cm)
10
3
(27.2 cm)
19
"
/
11
16
(50 cm)
" (69.75 cm)
32
" (71.65 cm)
13
64
A
B
D
D. 12" (30.5 cm) cabinet depth
E. 15" (38.1 cm) min. clearance
upper cabinet to countertop
F. 36" (91.4 cm) base cabinet
height
36" Model
16
/
"
1
2
(42 cm)
11
/
"
1
2
(29.2 cm)
2
/
"
3
8
(6 cm)
1"
(2.5 cm)
/
"
26"
4
(66 cm)
IMPORTANT: Mount this hood so that the bottom edge above
the cooking surface is at 27" (68.5 cm) minimum if a gas range
is used, or at 24" (61 cm) if an electric range is used. The
suggested maximum distance is 36" (91.4 cm). For household
use, please read the installation manual for specific application.
Check your cabinet dimensions prior to selecting your vent
hood.
Vent system must terminate to the outside, except for
nonvented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. A rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of the vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than one elbow is used.
Do not install two elbows together.
The vent system must have a damper.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
(15.2 cm)
35
"
/
15
16
(91.4 cm)
A. 36" Cabinet inner dimensions
MIN: 33
" (86.2 cm)
15
32
MAX: 34
" (88.1 cm)
11
16

Venting Requirements

(vented models only)
6"
A
1"
(2.5 cm)
10
"
/
3
4
(27.2 cm)
19
/
"
11
16
(50 cm)
5