When the water temperature has reached the set value,
as a condition also at the same time as that described in par.4.4.1,
the output is automatically brought
MODULATION status.
As for idro model stove, when the water temperature parameter
can't be reached, the activation of led [ A ] starts.
4.4.3 Restart from STANDBY
After shutdown, the stove goes to cooling status, bringing the fume
extractor speed to the set value for brazier cleaning. Relighting
occurs as soon as the room temperature reach the SET value.
4.4.4 Cleaning the brazier
During normal operation in work mode, the 'BRAZIER CLEANING'
mode is activated at fixed intervals for a set duration.
4.4.5 Water heater with heat exchanger quickly
When hot water is required, the display shows the word SCAM HEALTH and LED lights shown from the tap. The
function, however, is only executed if the stove is lit, and has reached a sufficient temperature inside the camera.
In the remaining cases the service is not provided.
4.4.6 Water heater with storage tank
This type of installation requires the use of an external thermostat, which measures the temperature of the water of
the kettle. When the temperature drops below the set temperature of SET in the external thermostat activates the
function of health, the display shows the message of the stove and boiler HEALTH LED lights shown from the tap
until the request is satisfied.
If the stove is in the HOLD step REQUEST automatically turns on and you put in WORK. Once the temperature of
water in the camera work, you turn the water supply to the boiler.
SET When the temperature of the tank is met, the oven converts waste heat to the heating for about 2 minutes and
then, if there is another request, it waits or REQUEST MODULATION, according to the settings ( see prg. 4.6.5).
If the stove is in the OFF state, no lights and does not provide the service.
4.4.7 System with puffer / heat storage
This type of installation requires the use of an external thermostat, which measures the temperature of the puffer.
When the temperature is lowered below the temperature of SET set in the external thermostat, in the stove display
shows the message WATER PUFFER or BOILER WATER and light up the 2 LEDs respectively indicated by the tap
and from the radiator as it can meet the plant heating system.
If the stove is in the HOLD step REQUEST automatically turns on and goes into WORK and reached the working
temperature of the water in the camera, you turn the water supply to the puffer.
SET When the temperature of the puffer is satisfied, the stove is placed in a HOLD REQUEST (it is recommended to
set the function ON STAND-BY, see prg. 4.6.5).
If the stove is in the OFF state, no lights and does not provide the service.
to the min. value,
Dialogue box
53
Room temperature
Clock
Dialogue
Water temperature
box
Set output
Clock
T-FLAVIA30 **