SAUNA HEATER STONES

Quality stones meet the following requirements:
-
Sauna stones should withstand heat and heat variation caused by vaporisation of the water thrown on the
stones.
-
Stones should be rinsed before use in order to avoid odour and dust.
-
Sauna stones should have an uneven surface to supply a larger surface for the water to evaporate from.
-
Sauna stones should be large enough, measuring about 80–120 mm to allow good ventilation between the stones. This
extends the useful life of the heating elements. The maximum stone capacity is about 60kg
-
Sauna stones should be piled sparsely in order to enhance ventilation between the stones. Do not bend the heating
elements together or against the frame.
-
Rearrange the stones regularly (at least once a year) and replace small and broken stones with new, larger stones.
-
Stones are piled so that they cover the heating elements. Do not, however, pile a large heap of stones on the heating
elements. Any small stones in the package of stones must not be piled on the sauna heater.
-
The warranty does not cover defects resulting from poor ventilation caused by small and tightly packed stones.
-
Structural clay tiles are not allowed. They may cause damage to the sauna heater that will not be covered
by the warranty.
-
Do not use soapstone as sauna rocks. Any damages resulting from this will not be covered by the stove
warranty.
-
Do not use lava stone as sauna rocks. Any damages resulting from this will not be covered by the stove
warranty.
-
DO NOT USE THE HEATER WITHOUT STONES.

Installing the sensor near a supply air vent

The sauna room air should be exchanged six times in an
hour. The diameter of the supply air pipe should be
between 50 and 100 mm.
A circular air supply vent (360°) must be
installed at least 1000 mm away from the sensor.
An air supply vent with a flow-directing panel
(180°) must be installed at least 500 mm away from
the sensor. Air flow must be directed away from the
sensor.
LAAVA
SKLE
and
360°
180°
Sensor
1000 mm
500 mm
Sensor
4