Functional Description; General Points; Putting Into Operation - SATA SATAjet 1000 K Mode D'emploi

Masquer les pouces Voir aussi pour SATAjet 1000 K:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Operating instructions SATAjet 1000 K (RP/HVLP), H RP
1.3 Technical Data
(SATAjet 1000 H RP version)
• Spray gun with nozzle 1.6 RP, 1 l aluminium suction cup,
paint strainer and anti-drip device
• Air consumption: 9.7 cfm at 22 psi
• Recommanded gun inlet pressure 22 - 36 psi

2. Functional Description

2.1 General Points

The SATAjet 1000 K RP/HVLP, SATAjet 1000 H RP paint spray gun is designed for spraying paints
and laquers as well as other media (Nozzle size depends on spray viscosity). Materials that are abra-
sive, acidic or contain benzine must not be used. The compressed air supply required for spraying is
fed to the air connection screwed into the gun grip. Squeezing the trigger as far as the first pressure
point opens the air valve (pre-air control). When the trigger is squeezed further, the paint needle is
pulled out of the paint nozzle. The spraying medium then flows unpressurized out of the paint nozzle
due to gravity and is simultaneously atomized by the compressed air that flows the air nozzle.
The cup lid is equipped with a drip stop that prevents the material from escaping from the vent hole.
3. Construction
1
Nozzle set (air cap visible only)
2
Self tensioning needle packing (not visible)
3
Trigger
4
Self tensioning air piston packing
(not visible)
5
Stepless regulation for round and flat spray
6
ColorCodeSystem
7
Air connection G ¼ outside
8
Air piston (not visible)
9
Fixing screw

4. Putting into Operation

Before putting into operation, and especially after each cleaning and any repair work, check to
see that all screws and nuts are tight. This applies in particular for the material flow control screw
(counter nut), the round/flat spray control (pos. 5) as well as the fixing screw (pos. 9) for the air
micrometer. The paint spray gun has been treated with an anticorrosive agent before leaving the
factory and must therefore be flushed out thoroughly with thinner before use. For servicing/repair
work of any kind, the system must be devoid of pressure, i.e. disconnected from the air supply.
Failure to respect this safety warning may result in damage and injuries, even death at worst. SATA
does not take any responsibility for possible results of such failure.
Material connection with:
SATAjet 1000 K RP/HVLP
a) Connect material hose of pressure pot,
respectively pump to the spray gun.
b) Adjust requested atomisation pressure
with pulled trigger. Then adjust material
feed pressure with pulled trigger. Please
check spray pattern on paper or other
suitable substrate and adjust pressure
IX.2
accordingly, if necessary.
10 Air micrometer
11 Fluid adjustment
12 Material sieve (not visible)
- only with SATAjet 1000 H
13 Non-drip device (not visible)
- only with SATAjet 1000 H
14 Paint tube (optional)
- only with SATAjet 1000 K
15 Suction cup
- only with SATAjet 1000 H
SATAjet 1000 H RP
c) Please mount the suction cup lid fitting in a
way that the lock for the cup lid faces
towards the nozzle (please see spare part
drawing).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Satajet 1000 k rpSatajet 1000 k hvlpSatajet 1000 h rpJet 1000 bJet 1000 b rpJet 1000 b hvlp

Table des Matières