Lenze ECSDS Série Instructions De Montage page 112

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5
Electrical installation
Power terminals
Motor holding brake connection
5.2.3.3
Requirements on the brake cables
Use a Lenze system cable with integrated brake cable.
ƒ
The shielding of the brake cable must be separated.
Length: max. 50 m
ƒ
If a separately installed brake cable is required, lay it in a shielded manner.
ƒ
)
Note!
Due to the monitoring circuit of the brake connection, an additional
constant voltage drop of 1.5 V is produced. The voltage drop can be
compensated by a higher voltage at the cable entry.
The voltage required at X6/B+ and X6/B− for the Lenze system cables is
calculated as follows:
[V] + U
U
K
V
Voltage required at 6X/B+ and X6/B− [V]
co
mp
V
Rated operating voltage of the brake [V]
B
L
Length of the brake cable [m]
L
I
Brake current [A]
B
X6
F 1.6 A
+23 ... +30 V DC
Fig. 5−4
Connection of the motor holding brake to X25
"
112
V
[V] ) 0.08
m @ A
B
X25
B+
B-
BD2
"
"
_
max. 1.5 A
HF−shield termination by large−surface connection to functional earth (see
Mounting Instructions for ECSZS000X0B shield mounting kit)
@ L
[m] @ I
[A] ) 1.5 [V]
L
B
BD1
_
M
3~
+
l
ECSXA017
EDKCSDX064 DE/EN/FR 3.0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecsdp sérieEcsdm sérieEcsda sérieEcs

Table des Matières