Installation Instructions; Install Leveling Legs; Make Electrical Connection - U.s.a - Whirlpool W11555816A Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

INSTALL LEVELING LEGS

1.
Prepare dryer for leveling legs
A. 3/8" NPT dryer pipe
Firmly grasp dryer body (not console panel) and gently lay dryer
down on back cardboard corner posts.
IMPORTANT: If laying dryer on its back, use the cardboard
corner posts the dryer was packed with to avoid damaging the
back of the dryer.
2.
Screw in leveling legs
Using a wrench and tape measure, screw leveling legs into leg
holes until bottom of foot is approximately 1" (25 mm) from
bottom of dryer.
Now stand the dryer on its feet. Slide the dryer until it is close
to its final location. Leave enough room to connect the exhaust
vent.
For mobile home use
Gas dryers must be securely fastened to the floor. Mobile home
installations require a MobileHome Installation Hold-down Kit. For
ordering information please reference the "Quick Reference
Guide."
18

MAKE ELECTRICAL CONNECTION - U.S.A.

WARNING
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power
2. Remove hold-down screw and terminal block cover
NOTE: Your terminal block cover may be in a different location.
Fire Hazard