4. Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Insert tab of terminal block
cover into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Venting Requirements."
Optional 3-Wire Connection (Power Supply
Cord Shown)
IMPORTANT: You must verify with a qualified electrician that this
grounding method is acceptable before connecting.
1. Prepare to connect neutral bond wire
and neutral wire
Install the correct strain relief for your electrical connection
method. Remove center terminal block screw (B). Remove
neutral bond wire (E) from green external bond conductor screw
(A).
2. Connect neutral bond wire and neutral
wire
Connect neutral bond wire (E) and neutral wire (white or center
wire) (C) of power supply cord or cable under center terminal
block screw (B). Tighten screw.
3. Connect remaining wires
Place remaining wires under outer terminal block screws. Tighten
screws.
4. Connect external ground wire
Connect a separate copper ground wire (G) from the green
external ground conductor screw (A) to an adequate ground.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw. Now, go to "Venting
Requirements."
23