3. Connect neutral bond wire and neutral
Connect neutral bond wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct wire
cable under center screw of terminal block (B). Squeeze hooked
ends together and tighten screw.
4. Connect ground wire
Connect ground wire (green or bare) (F) of direct wire cable
under green external ground conductor screw (A). Tighten screw.
5. Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Insert tab of terminal block
cover into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Venting Requirements."
22
wire
3-Wire Direct Wire Connection
IMPORTANT: Use where local codes permit connecting cabinet-
ground conductor to neutral wire.
1. Prepare your 3-wire cable for direct
connection
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
may be moved if needed.
Strip 3½" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
2. Remove center screw
Remove center terminal block screw (B).
3. Connect neutral wire
Place hooked end of neutral wire (white or center) (C) of direct
wire cable under center terminal block screw (B). Squeeze
hooked end together. Tighten screw.