OPE N DOOR AL ARM
• If any door remains open for more than 3 minutes, a continuous sound will be emitted. You can
deactivate it by pressing any button on the control panel, but it will be reset after 3 minutes if the
door remains open.
• The alarm will not turn off until the door is closed.
P OW E R FAI LUR E M E MORY
• In the event of a power outage, the refrigerator will maintain the operating status established
before the power outage when the power is restored.
D E L AYE D START
• To prevent damage to the refrigerator compressor in the event of a short-term power failure (i.e.,
less than 5 minutes), the compressor will not start immediately after being switched on.
OV E RHEATIN G AL ARM (O NLY AF T E R P OWE R FA ILUR E )
• When the cooling system is turned on, if the freezer sensor temperature is higher than -10°C, the
freezer zone digits will flash on the display.
• The freezer temperature can be displayed by pressing any key, and the normal displayªIt will be
reset by pressing any button again or after 10 seconds.
FAU LT AL AR M
• If E0, E1, E2, EH, EC or EE appears on the control panel, it indicates that there is a fault in the
refrigerator. In this case, please contact customer service.
AN T I-C ON D E N SAT IO N ADJ UST ME NT
1. Press and hold the "Fridge" and "Care+" keys for 3 seconds to enter the "Special Program Work-
ing Status" setting program, the "SD" character will flash on the screen.
2. After 2 seconds, the current setting of the "Special Program" will be displayed, and the screen
will show "ON" or "OF" depending on the selected status.
3. Press the "Freezer" key to set the working status to "ON". This setting will be memorized if no
key is pressed within 5 seconds, and the current program will exit to enter the normal operating
program.
4. After 5 minutes have passed after setting the "Special Program Working Status" to "ON", press
the "Fridge" key for 3 seconds while holding down the "Function" key to enter the anti-conden-
sation setting program.
5. When the "FL" character appears on the display, press the "Fridge" key to check the current sta-
tus of the anti-condensation function, which is "ON" by default (the display will show "1").
6. Then press the "Freezer" key to change the setting between 1 ("ON") and 0 ("OF"). When the
anti-condensation mode is set to "oF", this mode is off.
7. The function setting will not be memorized and will remain "on" when the system is turned back
on. After 10 seconds after the above setting, the current program will automatically exit if there
is no key operation, and the normal operating program will start.
• Do not access this setting during use, this function is used for testing and adjustment purposes.