to propane supply, operating or hot. Severe burns and electrical
shock can occur.
OBSERVED FAULT
Fan does not turn when heater is
plugged in
Heater will not ignite
Heater shuts down while run-
ning
only in areas free of
high dust content.
TECHNICAL SERVICE
You may have further questions about this heater.
If so, contact DESA Heating Productsʼ Technical
Service Department at 1-866-672-6040. When
calling, please have your model and serial numbers
of your heater ready.
You can also visit DESA Heating Productsʼ Techni-
cal Service web site at www.desatech.com.
8
Downloaded from
www.Manualslib.com
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, connected
POSSIBLE CAUSE
1. No electrical power to heater
2. Fan hitting inside of heater
3. Fan blades bent
4. Defective motor
1. User did not follow installa-
2. No spark at ignitor. See Ig-
1. Propane supply may be inad-
2. High surrounding air tem-
3. Restricted air flow
WARNING: Use
4. Damaged fan
5. Excessive dust or debris in
manuals search engine
shell
tion or operation instructions
properly
nitor, page 7. If you see spark
at ignitor, have heater serviced
by qualified service person. If
no spark seen:
A) Loose or disconnected
ignitor wire
B) Wrong spark gap
C) Bad ignitor electrode
equate
perature causing thermal limit
device to shut down heater.
surrounding area
ACCESSORY
Purchase accessories and parts from your nearest
dealer or service center. If your dealer or service
center can not supply an accessory or part, call
DESA Industriesʼ Parts Department at 1-905-826-
8010. You can also write to the address listed on
the back page of this manual.
THERMOSTAT - HA1210
www.desatech.com
REMEDY
1. Check voltage to electrical
outlet. If voltage is good, check
heater power cord for breaks
2. Adjust motor/fan mount to
keep fan from hitting inside of
heater shell. Bend fan mount
if necessary
3. Replace fan. See Fan, page 6
4. Replace motor
1. Repeat installation and operation
instructions. See Installation,
page 4 and Operation, page 5
2. A) Check ignitor wire. Tighten
or reattach loose ignitor wire.
B) Assure gap between ignitor
electrode and target plate is
0.13"0/.15" (3.3/3.8 mm). Do
not bend electrode. Doing so
may cause it to break
C) Replace ignitor electrode
1. A) Refill tank
B) Provide additional and/or
larger tanks. See Propane
Supply, page 3
2. This can happen when running
heater in temperatures above
85° F (29˚ C). Run heater in
cooler temperatures
3. Check heater inlet and outlet.
Remove any obstructions
4. Replace fan. See Fan, page 6
5. Clean heater. See Mainte-
nance, page 6