Condition
LEDs on Battery
Battery jams when
being inserted in
battery compartment.
Charge process does
1 LED glows red.
not start when
battery is inserted in
the charger.

18.2 Troubleshooting Charger

Condition
LED on Charger
Battery not being
LED flashes red.
charged.
50
Cause
Normal battery life has
been exceeded.
Guides or contacts in
battery compartment dirty.
Battery too hot or too cold. ► Leave battery in the charger.
Cause
No electrical contact
between charger and
battery.
Malfunction in charger.
Remedy
► Replace the battery.
► Clean guides or contacts in battery compartment.
Charge process starts automatically as soon as
permissible temperature range is reached.
Remedy
► Remove the battery.
► Clean contacts on charger.
► Fit the battery.
► Do not use the charger and contact your STIHL
servicing dealer.