Extension Cable; Preparing The Mortar Spraying Machine; Spray Lance With Automatic Control; Spray Lance Without Automatic Control - WAGNER PlastCoat PC15 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Plast Coat 15
EDITION 09 /2004
8
2
1
3
7.6

EXTENSION CABLE

The cross section of the cable must be
min. 3 x 2.5 mm
Unwind extension cable completely. Make
sure that the couplings and plugs are in com-
plete working order.
Arrange the mains cable so that there is no
danger of it being tripped over.
Protect against damage, e.g., caused by it
being run over.
• Before connecting to the mains make sure that the mains
voltage is in accordance with the details on the rating plate.
• Only connect to the mains supply using a special distribu-
ting point, e.g., using a side distribution system with fault
current protection with INF ≤ 30 mA.
• Connect mortar spraying machine to the mains supply.
7.7

PREPARING THE MORTAR SPRAYING MACHINE

Recommended lubricant for the mortar hose
Water is not a satisfactory lubricant.
Danger of blockages!
Synthetic resin products
dispersion
PCC systems
• Fill 2–3 l synthetic resin dispersion or cellulose pasteinto the
receptacle.
• Caution: set changeover switch (4, fig. 15) to „0" before tur-
ning on the master switch (1, fig. 15).
• Turn master switch (1, fig. 15) to „1", the indicator lamp will
show that the machine is ready for operation.
• Set feed rate regulator (3) to„5".
5
7
14
4
6
2
.
–> synthetic resin
–> cellulose paste
• Turn changeover switch (4) to „AUTO" (remote control
using spray lance).
15
• Hold spray lance over an empty bucket.
7.8

SPRAY LANCE WITH AUTOMATIC CONTROL

• Open material tap (3, fig. 16) on the spray lance. Themortar
spraying machine will switch on.
7.9

SPRAY LANCE WITHOUT AUTOMATIC CONTROL

• Open material tap (3, fig.17) on the spray lance.Press remote
control switch (1, fig. 17). The mortar spraying machine will
switch on..
7.10
SPRAY LANCE WITH AUTOMATIC CONTROL
• When the synthetic resin dispersion or cellulose paste has
been pumped into the mortar hose – turn off device, turn
switching sleeve (1, fig. 16) by 90° in a clockwise direction as
far as it will go.
• Close material tap (3, fig. 16).
7.11
SPRAY LANCE WITHOUT AUTOMATIC CONTROL
• When the synthetic resin dispersion or cellulose paste has
been pumped into the mortar hose – turn off device with
remote control switch (1, fig. 17).
• Close material tap (3, fig. 17).
• Check viscosity of the coating material.
• Fill coating material into the receptacle. With mineral coa-
ting materials only fill the receptacle to half full.
GB
PLACING INTO OPERATION
3
2
4
1
45

Publicité

Table des Matières
loading