15.Maintenance and cleaning

ATTENTION!: BEFORE CARRYING OUT ANY MAINTENANCE WORK OR
CLEANING, FIRST DISCONNECT THE UNIT FROM THE VOLTAGE SUPPLY
BY MEANS OF THE GENERAL SWITCH. ALWAYS WEAR PROTECTIVE
GLOVES FOR CLEANING.
Food products can deteriorate due to microbes and bacteria.
Respecting hygiene norms is indispensable in order to guarantee protection of consumer health, as
well as respecting the chain of refrigeration, for which the sales point is the last controllable ring.
Cleaning of refrigeration units should be carried out as follows:
Cleaning of external parts (Daily / Weekly)
- On a weekly basis, clean the external parts of the unit, using neutral household detergents or soap
and water.
- Rinse with clean water and dry with a soft cloth.
- DO NOT use abrasive products or solvents that can affect the unit surface.
- DO NOT spray water or detergent directly on the electrical parts of the unit.
- DO NOT touch the unit with wet or damp hands or feet
- DO NOT use the unit if barefoot
- DO NOT use alcohol to clean the methacrylate parts (Plexiglas).
Cleaning of internal parts (Monthly)
Cleaning the unit's internal parts is done to destroy pathogenic micro-organisms so as to ensure
protection of merchandise.
Before beginning to clean the inside of the unit, it is necessary to:
- Completely remove all merchandise inside;
- Disconnect the unit's power supply using the main switch;
- Remove any removable parts, including display plates, grills, etc. These should be washed with
warm water and detergent that contains disinfectant, and then dried carefully;
- Carefully clean the tank, drip, and water discharge protection grill, eliminating all foreign bodies that
may have fallen into the suction grill, lifting the fan plate if necessary.
- If anomalous ice has formed, contact a Qualified Refrigeration Technician for assistance.
Complete the cleaning operation by reattaching the dry removable elements and by restoring the
electrical supply. Once internal operating temperature has been reached, the unit can be loaded with
the products to be displayed.
ATTENTION!: If using a water jet cleaner to clean the interior, use a LOW
PRESSURE system. Take special care NOT direct the jet onto painted or plasticised
surfaces and keep a minimum distance of 30 cm from the surface to be cleaned (Fig.
4 Rif. 3).
N.B.Avoid wetting fans, lights, electric cables, and all electrical devices in general during
cleaning operations.

16.Superstructure (Fig. 7)

The refrigeration unit line Aries115GA-Aries150GA can be supplied with 1 or 2 shelved superstruc-
tures.
Assemble as follows:
1 -
Position and fix the shelf support uprights (a) on the side of the unit tank using the screws
supplied
2 -
Position and fix the shelf (d) on the upright using the screws supplied
3 -
If using a two-shelf superstructure, fix the frame (b) to the shelf (d) and then fix the second shelf
(c)
4 -
Connect the lighting (if applicable) and then fix the rise covers (e) using the screws supplied
Once complete, position the base trays (f) in the tank.
Base trays are provided with a groove for accommodation of the upright
ATTENTION!: Spread the load uniformly. Do not overload the shelves in a disorderly fashion.
The load must NEVER exceed 90 kg/m
N.B.All these operations should be performed by specialised technical personnel.