SAFETY STAT (fig. 9)
RX TP models. are. equipped. with.
safety. stat. (3). with. manual. reset-
ting..In.case.the.boiler.temperature.
exceeds. 95°C. the. safety. stat. will.
extinguish. the. pilot. burner. thus.
shutting.off.the.gas.flow.to.the.pilot.
and.main.burner.
Should. the. stat. trip. off,. it. will. be.
necessary.to.unscrew.the.cover.and.
reset. the. button. below. for. the. pilot.
burner.to.restart.
ATTENTION: Should the boiler
"lock out" again, you must call the
authorized technical staff.
SMOKE SAFETY DEVICE (fig. 10)
It. is. a. safety. device. which. controls.
the.correct.discharge.of.flue.gas.into.
the.atmophere.(3)..
The. control. device. stops. the. gas.
valve. if. the. flue. gas. is. descharged.
into. the. boiler. room. is. continuous.
way. and. in. such. quantities. as. to.
become.dangerous..
To.start.the.boiler.again,.switch.off.
the.power,.then.remove.the.smoke.
stat. cover. and. reset. the. button.
below...
ATTENTION: If the boiler stops
again, it will be necessary to call
the authorized technical staff.
GAS CONVERSION
Should. a. gas. other. than. that. for.
which.the.boiler.is.equipped.be.used,.
the.conversion.has.to.be.carried.out.
by. technical. personel. authorized. by.
the.manufacturer.
CLEANING AND MAINTENANCE
When.the.heating.is.turned.off.at.the.
end. of. the. season,. it. is. compulsory.
to.check.the.boiler.and.clean.it.
Maintenance
and
equipment and safety devices shall
be carried out only by authorized
technical personel.
DISPOSAL OF THE
EQUIPMENT
Once. it. reaches. the. end. of. its. ope-
rating.life,.the.equipment.MUST.BE.
46
RECYCLED.in.line.with.current.legi-
slation.
IT. MUST. NOT. be. disposed. of. toge-
ther.with.urban.waste.
It. can. be. handed. over. to. recycling.
centres,.if.there.are.any,.or.to.retai-
lers.that.offer.this.service.
Recycling. prevents. potential. dama-
ge. to. the. environment. and. health..
It. allows. to. recover. a. number. of.
recyclable. materials,. with. conside-
rable.savings.in.terms.of.money.and.
energy.
check
of
1
KEY
. 1. Boiler.stat
. 2. Thermometer
. 3. Smoke.stat
. 4. Hydrometer
3
4
2
Fig..10