INSTALLATION INSTRUCTIONS: Viewline 85 mm
Ruder position display
12
Electrical connection:
Electrical connection:
Note cable cross-sectional area!
Reducing the cable cross-sectional area leads to higher current
density, which can cause the cable cross-sectional area in question
to heat up!
When installing electrical cable, use the provided cable ducts and
harnesses, however, do not run cables parallel to ignition cables
or to cables that lead to large electricity consumers.
Fasten cables with cable ties or adhesive tape. Do not run cables over
moving parts. Do not attach cables to the steering column!
Ensure that cables are not subject to tensile, compressive or shearing
forces.
If cables are run through drill holes, protect them using rubber sleeves
or the like.
Use only one cable stripper to strip the cable. Adjust the stripper so
that stranded wires are not damaged or separated.
Only use a soft soldering process or commercially available crimp
connector to solder new cable connections!
Designations in the wiring diagram:
13
30 - terminal 30 - steady-state plus 12 V
15 - terminal 15 - connected (ignition) plus
58 - terminal 58 - lighting
31 - terminal 31 - ground
Anschluß 8polig
Connector set, 8-pin -
A2C59510850
F1 - fuse 5A quick-response
C1 - 8-pin MQS connector
You must comply with the wiring diagram.
Technische Änderungen vorbehalten - Technical details subject to change
TU00-0752-5907102
Use the following connector to connect the instrument:
Connector set, 8-pin - A2C59510850
The connector set is designed for a cable cross-section
of 0.25 - 0.5 mm
.
2
For other cross-sections, please use contacts made by Tyco.
Single contacts:
Tyco No. 1355718-1 for 0.14 – 0.22 mm
Tyco No. 963729-1 for 0.5 – 0.75 mm
Strip:
Tyco No. 1355717-1 for 0.14 – 0.22 mm
Tyco No. 963715-1 for 0.5 – 0.75 mm
Create a crimp connection using the contacts and the corre-
sponding cables. Follow the instructions of the hand pliers
manufacturer. Use the following for this:
Hand pliers
Tyco No. 539635-1
And the tool
Tyco No. 539682-2 for these hand pliers.
Pay special attention to whether the crimp barrel clutches all
individual wires in the cable, otherwise you risk a short circuit!
Only make crimp connections with cable crimping pliers. Follow the
safety instructions of the tool manufacturer.
Insulate exposed stranded wires to prevent short circuits.
Caution: Risk of short circuit if junctions are faulty or cables are
damaged.
Short circuits in the vehicle network can cause fires, battery explo-
sions and damages to other electronic systems. Consequently,
all power supply cable connections must be provided with weldable
connectors and sufficiently insulated.
Ensure ground connections are sound.
Faulty connections can cause short circuits. Only connect cables
according to the electrical wiring diagram.
If operating the instrument on power supply units, note that
the power supply unit must be stabilized and it must comply with
the following standard: DIN EN 61000, Parts 6-1 to 6-4.