Télécharger Imprimer la page

Atlantic CALYPSO Notice D'utilisation page 120

Les langues disponibles

Les langues disponibles

Warnings
Malfunction
observed
Condensate over-
flow (stagnant
water in the outside
unit's lower
housing)
Odour
Steam release
when drawing off.
Heat pump oper-
ates outside the off-
peak hours.
The heat pump runs
in short bursts, and
the electric backup
operates almost
continuously.
Control panel
failure or display
problem.
The
heat
pump
does not start
120
120
Installation
Possible cause
Condensate
obstructed.
No siphon on the pres-
sure relief valve
No water in the pressure
relief valve
Electric backup is contin-
uously switched on.
No
off-peak
detection.
Air temperature outside
the tolerance range
Outside
unit
malfunction
Evaporator
contaminated
Presence of non-con-
densable gases
No power supply.
Control panel fault
Power board fault.
Outside starting conditions
tank top too hot;
operating conditions out-
side of time slots;
anti-short cycle
drainage
Clean.
Install a siphon.
Fill the siphon.
Turn off the power sup-
ply and notify the heating
engineer.
signal
Check the wiring and trans-
mission of the off-peak
signal.
Modify the setting for the
Off-Peak hours signal.
Wait until temperature is
back within the tolerance
sensor
range
Inform the installer.
extremely
Clean the evaporator.
Empty and refill the circuit.
Check the power supply.
Replace the control panel.
Normal
in cooling mode (fewer
conditions).
Use
Diagnostics and
troubleshooting
operation.
Try

Chapitres

loading