7.3 Smart thermostat
parameters
1
3
A
Device name
Allows to change the name of the
device.
B
ITCS
Intelligent Temperature Control System :
This option is selected to anticipate the
heating/cooling of the programming
defined for more comfort.
Possible to parameter : Yes / No (by
default)
C
Open window
This parameter is used to detect if a
window is opened during heating
period.
Possible to parameter : Yes / No (by
default)
BT-ST03-RF-IOM-FR-W-EN-08-24
2
4
A
B
5s.
C
D
E
D
Offset ambient
Place the thermometer in the middle
of the room at about 1.5 m above the
floor. Record the temperature shown
after 1 hour. Example : Thermostat
measured value 20°C / Thermometer
measured value 20.5°C. Then put
+0.5°C in this parameter
Possible values : -3...+3°C
E
Hysteresis
Smallest value means high reactivity of
the boiler, highest value means the
boiler is not switching quickly. Example :
Set point is 20°C, hysteresis value is
1.0°C then boiler will switch OFF if tem-
perature is higher than 21°C and switch
ON if lower than 19°C
Possible values : 0.2...3.0°C