4. HYDRAULIC SYSTEM
ASSIGNEMENT
If your installation has several separate
hydraulic circuits containing their own
pumps or boilers, you may want to drive
each pump/boiler separately from specific
heating receivers or thermostatic actu-
ator(s). With Vision
create and control 1 hydraulic circuits. If at
least the receiver or thermostatic actuator
on the circuit has a demand, the linked
circuit receiver will operate and activate the
pump (and / or boiler).
STEP 1:
Define which device is assigned
to a hydraulic circuit
With the plan of your installation, define
which devices are on "circuit 1".
Then, pair and configure all these devices
on circuit 1.
, enter a zone (room) that belong
to circuit 1,
, and select one device of circuit 1
(radio receiver or radiator thermostatic head)
Now you have entered the
configuration menu of the device.
the menu "Heating settings" and make
sure that "Hydraulic heating" is selected
You can now select the
hydraulic circuit linked to this receiver (e.g.
circuit 1).
BT-ST03-RF-IOM-FR-W-EN-08-24
Wireless you can
®
Select
Repeat the procedure for each device of
the room (zone) you want to link to the
hydraulic circuit. Further devices can be
selected using the buttons
top of the device name.
Repeat the procedure for each room (zone)
that you want to link to hydraulic circuit.
STEP 2:
pairing radio receiver hydraulic
circuit with the smart ther-
mostat
For the circuit, link the circuit receiver to drive
the pump devices, valve drive or heat / cool
generator of the circuit.
Select "Circuit", then select the number
of the circuit, e.g. circuit 1. Put the radio
receiver in pairing mode (BT-WR03 RF).
Heat and Cool installations
If your installation includes both heating and
cooling functions, switch from heat to cool
manually :
then
There you will have the choice between
"Heating Only", "Cooling Only" or "Manual
Reversible".
or
at the
go in "H&C".