Make Gas Connection - KitchenAid KFGD500ESS Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Determine and mark edge of range in the cutout space. The
mounting bracket can be installed on either the left side or
right side of the cutout. Position mounting bracket in cutout
so that right (or left) edge of the bracket is 15/16" (2.4 cm)
from the marked edge of the range, as shown.
B
A. Anti-tip bracket
B. Mark edge of range
C. 15/16" (2.4 cm)
4. Drill two 1/8" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
A
B
A. #12 x 1
" (4.1 cm) screws
5
8
B. Anti-tip bracket
5. Using a Phillips screwdriver, mount anti-tip bracket to
the wall or floor with the two #12 x 1
provided.
8
A
C
Wall Mounting
A
B
A. #12 x 1
" (4.1 cm)screws
5
8
B Anti-tip bracket
5
" (4.1 cm) screws
8

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with propane gas
to the smaller thread ends of the flexible connector adapters
(see B and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and
the other adapter to the gas shutoff valve. Tighten both
adapters, being certain not to move or turn the gas pressure
regulator.
3. Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas pressure regulator too tight.
Making the connections too tight may crack the regulator
and cause a gas leak. Do not allow the regulator to turn
when tightening the fittings.
H
G
F
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 1/2"
(12.7 mm) male pipe thread)
D. Flexible connector
A
B
C
D
E
E. Manual gas shutoff valve
F. 1/2" or 3/4" (12.7 mm or 19
mm) gas pipe
G. Use pipe-joint compound.
H. Adapter

Publicité

Table des Matières
loading

Table des Matières