Install Anti-Tip Bracket

1. Remove the anti-tip bracket that is taped in the storage
drawer.
2. Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor you can use the wall
mounting method.
3. Determine and mark the edge of the range in the cutout
space. The mounting bracket can be installed on either the
left side or right side of the cutout. Position mounting bracket
in cutout so that right (or left) edge of the bracket is
⁹⁄₁₆" (14.5 mm) from the marked edge of the range, as shown.
B
A. Anti-tip bracket
B. Mark edge of range.
C. ⁹⁄₁₆" (14.5 mm)
4. Drill two ¹⁄₈" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See below.
Floor Mounting
A. #12 x 1⁵⁄₈" screws
B. Anti-tip bracket
8
A
C
A
B
Wall Mounting
A
A. #12 x 1⁵⁄₈" screws
B. Anti-tip bracket
5. Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1⁵⁄₈" screws provided.

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
B