Make Gas Connection - KitchenAid 30" (76.2 CM) Instructions D'installation

Masquer les pouces Voir aussi pour 30" (76.2 CM):
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical rigid pipe connection
A combination of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
B
A
C
A. ½" or ¾" gas pipe
B. Manual gas shutoff valve
C. Nipple
D. Union
E. 90° elbow

Make Gas Connection

I
H
J
G
F
E
D
F. Black iron pipe
G. Union
H. Nipple
I. 90° elbow (must have
½" male pipe thread)
J. Gas pressure regulator
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see C
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
B
D
A
C
A. ½" or ¾" gas pipe
B. Manual gas shutoff valve
C. Use pipe-joint compound.
D. Adapter
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from parts
package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light.
C
B
A
A. Burner base
B. Burner cap
C. Burner grate
H
F
E
G
E. Flexible connector
F. Adapter (must have ½" male
pipe thread)
G. Use pipe-joint compound.
H. Gas pressure regulator
B