S
ETTING THE DIFFUSION INTENSITY
The diffusion intensity is set by alternating diffusion and pause periods. The pause periods allow the scent to spread
throughout the space.
The diffuser uses two timers to set these alternating periods:
n
T1 = sets the diffusion duration
T2 = sets the pause duration
n
There is a choice of periods but prefer (T1+T2) periods that last approx. 2 minutes to ensure homogeneous diffusion.
The usual parameters are: 30s of diffusion/60s of pause or 60s of diffusion/60s of pause.
The setting is made by iteration until the desired result is obtained.
WARNING:
Depending on the scent chosen, a maximum intensity may be set so as to not exceed
the maximum exposure levels (set in the risk characterisation reports) for people in
the scented area. This value is provided by Scentys.
EXAMPLE: For a 60% intensity setting with a 2 minute (120s) period.
The diffusion parameters are as follows:
Diffusion duration T1 = ------ - x 120 = 72s = 1mn 12s
Pause duration
Intensity
T1
T1
Diffusion
Medium level
(60%)
T1
T1
Pause
NB: Adapt the parameter settings to your installation.
22/28
Intensity in % = -- - -- - -- - -- - -- - x 100
60
100
T2 = 120 - 72 = 48s
T1
T1
T1
T1
T1
T1
T1
TIMER PARAMETER SETTING INTERFACE
1
T1
2
(T1+T2)
Modify the diffusion timer value: Go to the "Paramètre" (Parameter) menu, then:
Go to the page for timer T1.
Modify the pause timer value: Go to the "Paramètre" (Parameter) menu, then:
T1
Check that the programmer is on the T2
timer page or go to the T2 timer page.
Time
Key
Parameter
Description
Timer number
TT1 = Diffusion duration timer T1
1
TT2 = Pause duration timer T2
Timer value
This is the timer duration in Minutes: Seconds
2
Press
to select the diffusion timer value
Once the value is changed, press
setting field.
return to the TT1 timer choice field, then
Press
or
to change the diffusion timer
press
to access the T2 pause timer
value.
setting page.
Press
to select the pause timer value
Now that all of the parameters are set,
setting field.
refer to the the Diffusion Parameter Setting
Press
or
to change the pause timer
section to return to the menu and restart
value.
the diffuser.
2
1
to
23/28