ETTING DIFFUSION TIMES
n
The diffusion calendar is used to manage the days and times when the diffuser will start and stop during the week,
so that they match the times when the area to be scented is in use.
n
The diffuser can handle up to four different operating periods so as to refine diffusion in line with days or periods
during the day. For each diffusion period, the days of the week when diffusion takes place can be validated along
with the times for starting and stopping the equipment.
Key
DIFFUSION CALENDAR
PARAMETER SETTING
INTERFACE
1
3
2
4
5
EXAMPLE: For the following diffusion calendar, programming is broken down into four ranges:
00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 10h 11h 12h 13h 14h 15h 16h 17h 18h 19h 20h 21h 22h 23h 24h
Monday
Tuesday
{
Range A
Wednesday
{
Range C
Thursday
Friday
{
Range D
Saturday
{
Sunday
Range C
The diffusion parameters are as follows:
NB: The parameters need to be adapted to suit your installation and every range does not have to be programmed.
20/28
Parameter
Description
Diffusion
H1 = Clock 1
1
calendar name
The programming unit has a single clock called H1
Operating ranges
4 operating ranges are available: A, B, C, D.
2
During operation, these ranges are cumulated:
the block is valid for all of the selected ranges
Diffusion days
Diffusion day:
3
0: Monday, 1: Tuesday, 2: Wednesday, 3: Thursday,
4: Friday, 5: Saturday, 6: Sunday.
Non diffusion days are shown by a -
Range start tim
This is the start of operation time
4
(2)
in Hours: Minutes format (00:00 to 23:59).
Range stop time
This is the end of operation time
5
(2)
in Hours: Minutes format (00:00 to 23:59).
A
B
C
D
To change operating range: Go to the "Paramètre" (Parameter) menu, then:
Go to the diffusion time parameter setting
range.
Select the operating days in a range: Go to the "Paramètre" (Parameter) menu, then:
Go to the diffusion time parameter setting
page and check that the programmer is set
to the desired range or select it using the
previous step.
Selection the time to start a range: Go to the "Paramètre" (Parameter) menu, then:
}
Range B
Go to the diffusion time parameter setting
page and check that the programmer is set
to the desired range or select it.
Selection the time to stop a range: Go to the "Paramètre" (Parameter) menu, then:
Go to the diffusion time parameter setting
page and check that the programmer is set
to the desired range or select it.
2
1
Press
until the operating range field is
Then you can move to set the parameters for
selected. Then press
until the desired
the selected range.
operating range is reached.
2
1
Press
until the field for the day to set is
Repeat the operation for every day to be set.
selected. Press
to chose the state of the
You can now configure the operating times.
selected day (digit = day with diffusion, - =
day without diffusion, 0=Monday, 6=Sunday)
2
1
Press
until the start time field is selected.
Press
to access the start minutes time
Press
to change the start hour time value.
value and change it if necessary by
pressing
2
1
Press
until the stop hours time field is
Press
to access the stop minutes time
selected.
value and change it if necessary by
Press
to change the stop hour time
pressing
value.
Clock parameter setting is complete, you
can then go on to configure the intensity.
.
.