Assembly Instructions - Franke AQUA109 Notice De Montage Et De Mise En Service

Robinetterie pour installation encastrée
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
8.

Assembly Instructions

Warning!
• Operate the product only with safety extra low voltage (SELV). Do not earth the
components.
• The power supply (to be provided by the customer) must be set up outside of the wet
area, in a separate room.
• Secure the electric connection with an earth leakage circuit breaker (RCD).
Failure to observe can mean risk of death or material damage, e. g. from electric shock or
fire.
Important!
Before installing, flush the pipes in compliance with DIN 1988.
8.1
Connect to the water supply.
8.2
Insert the solenoid valve with the seals.
Check the direction of flow (a).
8.3
Make the cut-out for the sensor module (see drawing).
• Urinal (b):
The groove for the anti-twist feature must face downwards.
• Washing/showering (c):
The groove for the anti-twist feature must face upwards.
Top thickness max. 30 mm
8.4
Guide the sensor module (g) through the cut-out provided.
• Urinal (b):
The groove for the anti-twist feature must face downwards. When the sensor is
connected, the LED flashes at the top.
• Washing/showering (c):
The groove for the anti-twist feature must face upwards. When the sensor is
connected, the LED flashes at the bottom.
8.5
Slide the disc (f) on to the sensor module.
8.6
Use the nut (e) to fasten the sensor module.
8.7
Use the adapter cable (k) and the extension (h) to connect the solenoid valve (i) and the
sensor module (g).
8.8
Connect the connecting line (l) to the sensor module (g).
• The LED flashes.
6