9083577
4.3 Never use the cord to carry the tool.
4.4 Place the electrical cord in a position that prevents it from
coming into contact with the tool and getting caught by the
workpiece. The cord should always stay behind the tool.
5.
Do not allow people, mobile equipment or vehicles to pass over
unprotected power cords.
6.
When operating a tool outside, use an outdoor extension cord
marked W-A or W. These cords are rated for outdoor use and
reduce the risk of electric shock.
7.
When using more than one extension cord, or if you are using a
single extension cord for more than one tool, please adhere to the
specifications found in the table below.
AMPERES
(FULL LOAD)
0–2.0
2.1–3.4
3.5–5.0
5.1–7.0
7.1–12.0
12.1–16.0
16.1–20.0
GRAUND FAULT CIRCUIT INTERRUPTER
This tool comes equipped with a ground fault circuit interrupter (GFCI),
which protects the operator against shock in the event of a short circuit.
Note that the tool's main power supply cord is not GFCI protected
between the GFCI unit and the plug in the outlet.
Test the GFCI before each use by accomplishing the following:
1.
Plug the GFCI power plug into a grounded outlet.
2.
Press the TEST button. This will cause the GFCI indicator light to
turn off and power to the machine will be cut.
2.1 If the light does not turn off, do not use the tool until it is
properly inspected and repaired.
3.
Upon completion of a successful test, push the reset button to
restore power
8
Power-Feed Electric Drain Cleaner
CORD LENGTH
25 FT
50 FT
18
18
18
18
18
18
18
16
18
14
14
12
12
10
75 FT
100 FT
18
18
18
16
16
14
14
12
12
10
10
-
-
-
For technical questions call 1-800-665-8685
V1.0
150 FT
16
14
12
12
-
-
-