If these two numbers do not match, please check the settings on the charger and the battery itself. It may
be that the LiPo battery has been completely discharged, or a cell may be faulty. In this case, the battery
should not be charged, as there is a risk of fire and explosion!
You can return to the previous configuration menu using the „BATT.TYPE/STOP" button.
• If the two numbers match, you can start the charging process by briefly pushing the „START/ENTER" button.
• Once the charging process has been started, various information about the
current charging progress is shown on the display.
Example:
At the upper left, the rechargeable battery type and the cell number are displayed („Li3S" = Lithium rechargeable
battery with 3 cells); the charging current is shown in the upper middle and the current rechargeable battery
voltage at the upper right.
The lower left shows the current rechargeable battery programme („CHG" = „CHARGE"), in the middle the
elapsed charging time and the charged capacity in mAh are displayed to the right of this.
Various information is indicated on the display during a charge/discharge process by repeatedly pressing the
button „DEC". If you do not push any button for a few seconds, the charger will return to the formal display.
Observe the information in chapter 18.
• Once the charging process has been completed, an audio signal is emitted (if it was not turned off).
If you wish to cancel the charging process, push the „BATT.TYPE/STOP" button.
Li3S 1.2A 12.59V
CHG 022:43 00682
61