Presets
P04 – Session Delay
The session delay allows a programmable amount of time at the begin-
ning of a session to get ready for the tanning session. The tanning ses-
sion time shown on the timer flashes during the session delay.
When parameter 04 is shown, the display will read 0.0 for no session de-
lay.
– Press
to go to P05 without changing the setting.
To enable the session delay:
– Press Reset once and then release it. The display will begin to flash.
– Press
or
to reach the desired setting.
Time is displayed from 0.0 to 10.0, with decimal representing tenths
of a minute. For example: 2.5 equals 2 minutes, 30 seconds.
– Press Reset once then release it.
The session delay is now set.
– Press
to go to Parameter 05 (P05).
P05 – Station Address
The station address allows the tanning unit to be identified for interface
with the CCS series controllers, the Intellitan Single Station Console, or
the Intellitan Protocol Interace (IPI) for your computer system.
When parameter 05 is shown, the display will read 0000 for station ad-
dress zero.
– Press
to go to P06 without changing the setting.
To change the station address:
– Press Reset once and then release it. The display will begin to flash.
– Press
or
to reach the desired address setting.
– Press Reset once then release it.
The station address is now set.
– Press
to go to Parameter 06 (P06).
P06 – Lamp Hour Accumulation Counter (On Current Lamp
Bank)
The lamp hour accumulation counter keeps track of the number of hours
on the current lamp bank. This is a resettable parameter that should be
reset to 0 when the lamps are changed. When current lamp hour accu-
mulation reaches 1000, a beep will chime each time the unit is turned on,
indicating that a lamp change is necessary. Chime will not sound if it has
been turned off through parameter 02. Parameters 6 and 32 are only edi-
table at password level 1.
When parameter 06 is shown, the display will read from 0000 to 9999.
– Press
to go to P07 without changing the setting.
To clear the lamp hour accumulation counter:
– Press Reset once and then release it. The display will begin to flash.
– Press and hold
until 0000 is displayed.
– Press Reset once then release it.
Lamp hour accumulation is now cleared.
– Press
to go to Parameter 07 (P07).