3.
Put the included plastic bag over the cyclone to prevent the dust in the filter from spreading.
4.
Lift the filter straight up.
5.
Seal the plastic bag with the used filter.
6.
7.
When changing the filter, check the gasket.
8.
A leaky gasket can cause the release of health-hazardous dust.
9.
Never use old gaskets or plagiarized filters.
10. Replaced filters must be placed in a resealable plastic bag.
Motor
The typical service life of a fan motor's original brushes is 600-700 hours. The brush can be replaced. The service
life of the second brush set is approx. 400 hours, while that of the third set is approx. 300 hours. After this time, the
motor is considered worn out and should be replaced.
Overheating
If the machine is at risk of overheating (for example, as a result of powerful throttling), the temperature guard will
trip and the machine will stop. The operator must then press the power switch to the OFF position, unplug from
the mains and wait 3-5 minutes for the machine to cool down. Then reset the temperature guard by pressing the
RESET button. Reconnect the power cord to the electrical outlet and restart the machine by pressing the power
switch to the ON position.
DC Chip Extractor