3.8. Remote control RS-232 Port

The built-in RS-232 port in the rear panel allows an external device to communicate with a MIMO SG unit
via serial connection. Said connection uses the TP-NET protocol syntax so to enable the external device to obtain
the value of any of the parameters of the MIMO SG unit (by "GET" commands) and/or modify said values ("SET"
commands). See the TP-NET protocol manual for more information.
The serial connection should comply with the following specifications:
Baud rate: 57600 (fixed, no auto negotiation)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None

3.9. Front panel controls and LED indicators

The following elements are available on the MIMO SG series front panel:
Input LED indicators: indicate the presence of audio signal at the unit's input, and its intensity level (green,
amber and red indicate in this order the increased intensity level)
Output LED indicators: indicate the presence of audio signal at the unit's output, and its intensity level
(green, amber and red indicate in this order the increased intensity level)
Status LED indicators (STATUS):
DATA: Off: there is no connection to EclerNet Manager even if connected to Ethernet. On:
o
connected to EclerNet Manager or to other third party application via TP-NET protocol. Flashing:
data traffic with EclerNet Manager or another application.
POWER: Illuminates when the unit is in operation. It flashes if there is an error in the unit or if
o
firmware is not correct. It also flashes when you update firmware

4. CLEANING

The front panel should not be cleaned with dissolvent or abrasive substances because silk-printing could be
damaged. To clean it, use a soft cloth slightly wet with water and neutral liquid soap; dry it with a clean cloth. Be
careful that water never gets into the unit through the holes of the front panel.
WIRING RS232 – DB9
RS232
DB9
Tx
Pin 2 (RxD)
Rx
Pin 3 (TxD)
Gnd
Pin 5 (Signal Gnd)