Ethernet Port For Programming And Control; Remote Port For Digital Remote Controls; Gpi Remote Control Ports - Ecler MIMO SC Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.5. ETHERNET port for programming and control

A RJ45 type connector allows connecting the equipment to an Ethernet network:
Management from EclerNet Manager application. Please refer to the EclerNet Manager Software manual
for more information.
Possibility of direct connection (point to point) between a computer and a MIMO SG unit.
Connection to third party other devices. (Crestron, AMX, Vity, Medialon, etc. Registered trademarks of their
manufacturers). Protocol used: Ecler TP-NET. See the TP-NET protocol manual for more information.
Connection to WPmSCREEN units (remote control of an entire network of EclerNet devices through
custom graphic panels).

3.6. REMOTE port for digital remote controls

The REMOTE port allows the connection of digital remote control devices, such as the
WPTOUCH wall panel or the MPAGE16 paging console. The REMOTE port is connected to the
digital control bus the remote devices are daisy-chained to, the last one being loaded with a
120 Ω termination resistor between CAN HIGH and CAN LOW.
Refer to the remote device documentation (WPTOUCH, MPAGE16, etc) for more
information about your connection and controls.
Please refer to the EclerNet Manager Software manual for more information about programming a MIMO
SG to manage the remote devices that are connected to the REMOTE port.

3.7. GPI Remote Control Ports

The rear panel of the MIMO SG offers 8 (MIMO88SG) or 12 (MIMO1212SG) GPI inputs for 0-10 VDC
continuous control voltage. Each of these inputs can be connected to an external physical device (potentiometer,
contact closure, continuously variable voltage 0-10V DC, etc.) and assigned to a MIMO SG function, as for
example:
Input, output channel or matrix crosspoint volume remote control by means of a WPmVOL physical
knob or an Ecler WPm Series' WPVOL-IR remote control
MUTE or SOLO activation/deactivation by means of a switch or contact closure
Recalling a preset with a push button or contact closure
GPI connectors are screw terminal blocks with three-contacts. The wiring is as follows:
Positive, + 10 VDC
Variable voltage, 0-10 VDC
Ground
Connecting cables can be up to 500 meters with a minimum section of 0.5 mm
Consult your ECLER dealer or www.ecler.com about the WP series remote control wall panels and other
accessories available for connection to the GPI port.
6
>
Pin +
Pin 
>
Pin ⊥
>
Examples of connection
2
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mimo88sgMimo1212sg

Table des Matières