Internal docking station:
Route the perimeter wire (2) in front of and
behind the docking station (1) for 0.6 m in
a straight line and at right angles to the
floor plate. Then follow the edge of the
mowing area with the perimeter wire.
If the offset drive home (passage) is
used, the perimeter wire must be
routed at least 1.5 m in front of and
behind the docking station in a
straight line and at right angles to
the floor plate. (
10.14)
0478 131 9934 A - EN
External docking station:
Route the perimeter wire (2) in front of and
behind the docking station (1) with a
clearance (A) and at right angles to the
floor plate. Then install a corridor.
(
11.10)
A freely travellable minimum clearance (B)
must be available for the robotic mower to
the side of the ground plate.
A = 0,5 m
B = 0,4 m
Further information on installation
of the external docking station is
contained in the Installation
examples section. (
Then follow the edge of the mowing area
with the perimeter wire.
Wire routing around the mowing area:
Route the perimeter wire (1) around the
mowing area and around any obstacles
(
11.8) and fasten it to the ground using
fixing pins (2). Check the clearances using
the iRuler. (
26.)
Avoid routing at acute angles (less than
90°). In acutely angled lawn corners,
fasten the perimeter wire (1) to the ground
with fixing pins (2) as illustrated.
11.5)