To program registers, here are the steps to follow depending on the chosen mode.
Example of possible configurations:
Case (without 100% event) with the 2 probes activated
•
Sampling : 10 minutes
•
Historisation : every hours (so every 6 samples)
FR
•
Transmission : every 2 hours (so every 2 historisations)
•
Sampling : 10 minutes
•
Historisation : at each sample
•
Transmission : maximum tolerated par ma frame (here in Sigfox RC1)
•
Sampling : 5 minutes
•
Historisation : every 15 minutes (so every 3 samples)
•
Transmission : every half-hours (so every 2 historisations)
EN
•
Sampling : every hours
•
Historisation : at each sample
•
Transmission : at each historisation
•
Sampling : every hours
•
Historisation : at each sample
•
Transmission : every 2 hours (so every 2 historisations)
•
Sampling : every minutes
•
Historisation : every 5 minutes (so every 5 samples)
•
Transmission : every 10 minutes (so every 2 historisations)
•
Sampling : every 10 minutes
•
Historisation : at each sample
•
Transmission : at each historisation
Reminder : In Sigfox RC1, the technology enables to have 5 samples in a frame (so 2 samples per probe if the probes are activated). If only one
probe is activated, it is possible to configure 5 in register S301 without losing data. If the 2 probes are activated, it is mandatory to configure at
maximum 2 in the register S301 to not lose data. If there is too much data for the capacity of the frame, the flag "configuration incoherency"
will appear in the concerned frame and the oldest samples will be lost.
Associated
Theoretical number of
configuration
periodic frame per day
•
321 = 300
•
320 = 6
12 frames
•
301 = 2
•
321 = 300
•
320 = 1
72 frames
•
301 = 2
•
321 = 150
•
320 = 3
48 frames
•
301 = 2
•
321 = 1800
•
320 = 1
24 frames
•
301 = 1
•
321 = 1800
•
320 = 1
12 frames
•
301 = 2
•
321 = 30
•
320 = 5
144 frames
•
301 = 2
•
321 = 300
•
320 = 1
144 frames
•
301 = 1