Jotul FS 44 Manuel D'installation page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
UNITED KINGDOM
Table of contents
1.0
Relationship to the authorities .................20
2.0
Technical data ............................................20
3.0
Before Installation ...................................... 21
3.0
Installation .................................................21
4.0
Installation completed ............................... 24
5.0
Optional Equipment .................................. 24
Figures ........................................................50
20
1.0
Relationship to the
authorities
Jøtul FS 44 - Jøtul I 400
is a freestanding product, which can be
positioned against inflammable walls at the distances
in fig. 1.
The installation of a fireplace must take place in accordance with
each country's laws and regulations. All local ordinances must be
complied with when the product is installed.
Installation instructions for the insert accompany the surround.
An installation manual with technical data for the insert
accompanies the insert. For day-to-day use, maintenance, service
work, etc. see the General user and maintenance manual.
Contact your local building authorities regarding restrictions and
installation requirements.
The installation can only be taken into use after it has been
inspected and found to be in good order by qualified personnel.
The product is tested and documented as freestanding products
in accordance with EN 13240.
The rating plate for the freestanding product comes with the
installation instructions for the surround. It should be positioned
in a suitably visible place.
2.0 Technical data
The following options are available for the surround:
Open high model
Open high model
• •
Open low model
Open low model
• •
Closed model
Closed model
Jøtul FS 44 - I 400
Minimum distance to ceiling:
Weight per part:
Part 1:
Bottom plate/shelf plate
Part 2:
Sides, (high)
Part 3:
Bearing element
Part 4:
Side and rear panels
Part 5:
Ventilation element
Part 6: Grate
Part 7:
Sides, (low)
Part 8:
Complete base/cowl
Part 9: Sealing plug
Part 10: Bottom plate, air intake
Flue pipe:
Technical data in acc. with EN 13229
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught:
Efficiency:
CO emissions (13% O
):
2
Flue gass temperature:
Operating mode:
"Intermittent combustion" here means normal use of a stove.
That is to say, if you want to continue producing heat, you add
more fuel as soon as the previous load of wood has burnt down
to embers.
described
300 mm
34 kg each
26 kg each
27 kg each
28 kg each
29 kg each
approx. 1 kg
10 kg each
39 kg each
1.3 kg each
28 kg each
Top-mounted
6,0 kW
7,3 g/s
12 Pa
74 %@ 6,0 kW
0,19 %
o
259
C
Intermittent

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

I 400

Table des Matières