4.2. Safety guidlines (see fi g. 1)
-Mains voltage and type of current have to correspond to the data on the type plate.
-Pull out mains plug before starting to work or maintenance on the pump, in the pond or aquarium
(disconnect the pump).
The pump should be placed so that it cannot fall in the water. Keep the pump dry. Fix the pump by
means of a string (A) which can pass through the hole at the back side of the pump. Caution! The
pump may travel due to the vibrations that result during operation. Ensure the pump is fixed by the
string (A) securely before operation.
The pump should be placed at higher level than water surface (B).
The pump is designed for indoor use only!
The pump should not be used, if mains connection, plug or housing are damaged. If the supply cord is
damaged, it must be replaced by the manufacturer, its service agent or similarly quali fied persons in
order to avoid a hazard. Any repair work should be done only by the manufacturer or by an authorized
repair shop who has on hand all the special tools.
Run a part of the cable downward in a curve so as to prevent water flowing freely along the cable to
the plug or the plug socket (C). In case plug or socket have got wet, do avoid any contact! Interrupt
current supply to the plug socket!
Run a part of the hose downward in a curve so as to prevent water flowing freely along the hose to
the pump (D). In case the pump has got wet, pull out mains plug!
-Do never hang up or transport the pump by the cable!
-Protect the pump from freezing in winter!
-Take special care in following these safety guidlines when children are near by.
4.3. Installation
-Order of setting up (see fi g. 1):
1.aerating pump, 2.hose approx. 10 cm, 3.non-return valve, 4.hose and 5.air stone.

5. Electrical connection

The appliance is supplied with line cord and plug. Do not carry or pull the unit by the line cord or plug.
Protect the plug and the line cord from heat, oils and sharp edges.
Check that the voltage shown on the label of the unit corresponds to the voltage of the
mains supply. The person responsible for the installation must ensure that all electrical
connections are earthed according to the electrical regulations of the authority in the area.
Connect the unit only to power supplies with residual current circuit breaker (RCCD) with
sensitivity of 30mA (DIN VDE 0100T739). (earth leakage system)

6. Orders of Spare parts

The quickest and cheapest way to order spare parts is on the web. Our web site www.tip-pumpen.de
offers a detailed internet shop for spares and enables customers to place an order with few clicks. In
the web we also supply relevant information and give free and technical advice on all our range, along
with latest news, trends and newest products on the market of garden pond pumps.

7. Maintenance and Remedy of faults

Prior to any maintenance disconnect the power supply to all units immersed.