Electrical Safety - Bosch ART 23 SL Notice Originale

Masquer les pouces Voir aussi pour ART 23 SL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
OBJ_BUCH-2058-004.book Page 11 Wednesday, August 9, 2017 11:28 AM
not place other objects on top of the
machine.
Replace worn or damaged parts for
safety.
Ensure replacement parts fitted are
Bosch-approved.
Do not operate the machine with-
out the trimmer attachment fitted.

Electrical Safety

Switch off and disconnect the ma-
chine before using manual-feed
button (see figure 9). This button
should only be used in the event of
an obstruction of the cutting line.
Warning! Switch off, remove plug
from mains before adjusting,
cleaning or if cable is cut, damaged
or entangled.
Your machine is double insulated for
safety and requires no earth connec-
tion. The operating voltage is 230 V AC,
50 Hz (for non-EU countries 220 V,
240 V as applicable). Only use ap-
proved extension cables. Contact your
Bosch Service Centre for details.
For increased electrical safety use a Re-
sidual Current Device (RCD) with a trip-
ping current of not more than 30 mA.
Always check your RCD every time you
use it.
Keep the supply cables away from mov-
ing hazardous parts and avoid damage
to the cables; this can lead to contact
with live parts.
The connections (plugs and sockets)
should be kept dry and off the ground.
The supply cables must be inspected
for signs of damage at regular intervals
Bosch Power Tools
and may only be used if in perfect con-
dition.
If the supply cable on the product is
damaged, it must only be replaced by a
Bosch Service Centre.
Only use approved extension cables.
Extension cords, cables, leads, reels
should only be used if they comply with
EN 61242/IEC 61242 or
IEC 60884-2-7.
If you want to use an extension cable
when operating your product, only the
following cable dimensions should be
used:
– Nominal Conductor Area of
2
1.25 mm
or 1.5 mm
– Maximum length of 30 m for a Cord
Extension Set or maximum length of
60 m for a Cable Reel with Residual
Current Device (RCD
Note: If an extension cable is used it
must be earthed and connected
through the plug to the earth cable of
your supply network in accordance
with prescribed safety regulations.
If in doubt contact a qualified electri-
cian or the nearest Bosch Service Cen-
tre.
WARNING! Inadequate exten-
sion cables can be dangerous.
Extension cable, plug and
socket must be of watertight con-
struction and intended for outdoor
use.
For products not sold in GB:
WARNING: For your safety, it is re-
quired that the plug attached to the
product is connected with the exten-
sion cord. The coupling of the exten-
English | 11
2
F 016 L81 728 | (9.8.17)

Publicité