IO-Link Data Dictionary
21.10.01.00065/03
Diagnostic Buffer - Details
Data Format of Single Entry (ISDU 132)
Bytes 0...1
Bytes 2...5
Diagnostic-Type (MSB first)
Counter cc1 (MSB first)
Data Format of Diagnostic Buffer (ISDU 131)
Bytes 0...5
Bytes 6...11
Bytes 12...17
Entry 1 (newest)
Entry 2
Entry 3
Encoding of Diagnostic-Type
Diagnostic-Type
Description
Notifications
0x1401
Notification: Device powered on
0x1402
Notification: Diagnostic buffer cleared
0x1403
Notification: Parameters restored to factory defaults
0x1404
Notification: Vacuum sensor calibrated successfully
0x1405
Notification: Manual mode entered
0x0405
Notification: Manual mode exited
0x14AA
Notification: Corrupted entry
Errors
0x1201
Error E01: Internal Error
0x1202
Error E02: Internal Error
0x1203
Error E03: Vacuum sensor calibration failed
0x1207
Error E07 appeared: Primary voltage US too low
0x0207
Error E07 disappeared: Primary voltage US too low
0x1208
Error E08 appeared: IO-Link communication interrupted
0x0208
Error E08 disappeared: IO-Link communication interrupted
0x120C
Error E12 appeared: Short-circuit at OUT2
0x020C
Error E12 disappeared: Short-circuit at OUT2
0x1211
Error E17 appeared: Primary voltage US too high
0x0211
Error E17 disappeared: Primary voltage US too high
0x1212
Error E18 appeared: Input pressure outside operating range
0x0212
Error E18 disappeared: Input pressure outside operating range
Condition Monitoring Warnings
0x1101
CM-Warning: Valve protection activated
0x1102
CM-Warning: Evacuation time t1 above limit [t-1]
0x1104
CM-Warning: Leakage rate above limit [-L-]
0x1108
CM-Warning: H1 not reached in suction cycle
0x1110
CM-Warning appeared: Free-flow vacuum > (H2-h2) but < H1
0x0110
CM-Warning disappeared: Free-flow vacuum > (H2-h2) but < H1
0x1120
CM-Warning appeared: Primary voltage US outside of optimal range
0x0120
CM-Warning disappeared: Primary voltage US outside of optimal range
0x1180
CM-Warning appeared: Input pressure outside of operating range
0x0180
CM-Warning disappeared: Input pressure outside of operating range
EPC Data Buffer - Details
Data Format of Single Entry (ISDU 134)
Bytes 0...1
Bytes 2...3
Evacuation time t1 (MSB first)
Leakage rate (MSB first)
Data Format of EPC Data Buffer (ISDU 133)
Bytes 0...9
Bytes 10...19
Bytes 20...29
Entry 1 (newest)
Entry 2
Entry 3
Implemented IO-Link Events
Event code
Event name
0x1000
General malfunction
0x5100
General power supply fault
0x5110
Primary supply voltage over-run
0x8C01
Simulation active
0x1800
Vacuum calibration OK
0x1801
Vacuum calibration failed
0x1802
System pressure fault
J. Schmalz GmbH
...
...
Bytes 4...5
Bytes 6...9
Free-flow vacuum (MSB first)
Counter cc1 (MSB first)
...
...
Event type
Remark
Error
Internal error e.g. E01 / E02
Error
Primary supply voltage US too low
Warning
Primary supply voltage US too high
Warning
Manual mode active
Notification
Notification
Warning
System pressure outside of operating range
4 of 4
J. Schmalz GmbH
Johannes-Schmalz-Str. 1
D 72293 Glatten
Tel.: +49(0)7443/2403-0
info@schmalz.de
Remark
Counter value cc1 of when the entry was recorded
Bytes 223...228
Remark
Entry 38 (oldest)
Buffer of 38 entries (newest to oldest) with encoding as in ISDU 131
Remark
Single entry was written incorrectly - do not evaluate
Remains until next power-on
Remains until next power-on
Remains until next suction cycle
Remains until next suction cycle
Remains until next suction cycle
Remains until next suction cycle
Remark
Counter value cc1 of when the data was recorded
Bytes 90...99
Remark
Entry 10 (oldest)
Buffer of 10 entries (newest to oldest) with encoding as in ISDU 133
SCPSi series
07.03.2022
SCPSi Data Dictionary