Capacitive Load Boundary for Constant Voltage (CV) Operation

The following figures show the boundary limitations for capacitive loads with equivalent series
resistance for constant voltage operation. Operation below the two marginal stability lines when
operating with either the High or Low
bandwidth setting
may result in output instability.
500 V units
950 V units
950 V, 10 kW unit
500 V, 10 kW unit
500 V, 5 kW unit

Voltage Programming Response (All Models)

The following graph shows the output voltage programming response characteristic. This applies for
small signals only, under no load conditions.