Fault Table Part 1 - Wetrok Master Sweep 97 Plus Manuel D'utilisation Original

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63

8.1 Fault table Part 1

Fault
Device is running with difficulty
or roughly
The device is switched off
Device can't be switched on
Bristles are bent
Cause
Device is contaminated
Broom blocked
Contaminated broom drives
Height adjustment set too low
Plate broom pressure too high
Battery charge too low. LED display on
the sweeping machine shows red light
Plate brooms do not rotate
Fine sweeping roll does not rotate
Plate broom pressure too high
Broom blocked
Overload protection active
Battery charge too low. LED display
shows red light. Device
sweeping machine
switched off electronically
F1 fuse is defective
F1 fuse is defective
Disconnected battery lead
Deep discharge battery
Improper storage
Remedy
Clean sweeping machine. See Chapter 9.5
Section "Clean the device"
Remove blockage, see Chapter 9.3 Section
"Remove blockage"
Clean broom drives. See Chapter 9.5 Section
"Clean the device"
Set height adjustment, See Chapter 7.2
in Section "Height adjustment of the plate
brooms"
Charge battery. See Chapter 6.3 Section
"Charging battery"
Contact Service
Set height adjustment. See Chapter 7.2
in Section "Height adjustment of the plate
brooms"
Clean sweeping machine. See Chapter 9.5
Section "Clean the device"
Remove blockage, see Chapter 7.5 Section
"Overload protection"
on the
Charge battery. See Chapter 6.3 Section
"Charging battery"
Check F1 fuse and exchange. See Chapter
8.4 Section "Take out the F1 fuse and check"
Check F1 fuse and exchange. See Chapter
8.4 Section "Take out the F1 fuse and check"
Connect battery lead. See Chapter 6.2 Section
"Connect battery leads"
Contact Service
Align the bristles, see Chapter 9.4 Section
"Align bristles"
Troubleshooting
53
EN

Publicité

Table des Matières
loading

Table des Matières