Télécharger Imprimer la page

DeWalt XR DCF809L2T Traduction De La Notice D'instructions Originale page 34

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
EnGLIsh
installing attachments or accessories. An accidental
start-up can cause injury.
Proper Hand Position (Fig. D)

WARNING: To reduce the risk of serious personal injury,
ALWAYS use proper hand position as shown.

WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
sudden reaction.
Proper hand position requires one hand on the main handle 
Variable Speed Trigger Switch (Fig. A, E)
To turn the tool on, squeeze the trigger switch 
the tool off, release the trigger switch. Your tool is equipped
with a brake. The chuck will stop when the trigger switch is
fully released.
The variable speed switch enables you to start the application at
a slow speed. The further you squeeze the trigger, the faster the
tool will operate. For maximum tool life, use variable speed only
for starting holes or fasteners.
nOTE: Continuous use in variable speed range is not
recommended. It may damage the switch and should
be avoided.
Forward/Reverse Control Button (Fig. A, E)
A forward/reverse control button 
the tool and also serves as a lock-off button.
To select forward rotation, release the trigger switch and
depress the forward/reverse control button on the right side of
the tool.
To select reverse, depress the forward/reverse control button on
the left side of the tool. The centre position of the control button
locks the tool in the off position. When changing the position of
the control button, be sure the trigger is released.
nOTE: The first time the tool is run after changing the direction
of rotation, you may hear a click on start up. This is normal and
does not indicate a problem.
Worklights (Fig. A)
There are three worklights 
 7 
chuck 
. The worklights are activated when the trigger switch
 6 
is depressed.
When the trigger is released, the worklight will stay illuminated
for up to 20 seconds. If the trigger switch remains depressed,
the worklights will remain on.
nOTE: The worklights are for lighting the immediate work
surface and are not intended to be used as a flashlight.
Quick-Release Chuck (Fig. A, F, G)

WARNING: Use only impact accessories. Non-impact
accessories may break and cause a hazardous condition.
Inspect accessory prior to use to ensure that it con tains
no cracks.
32
. To turn
 3 
 4 
determines the direction of
located around the 6.35 mm hex
nOTE: The chuck accepts 6.35 mm hex bit tips only. Using
25 mm bits allows better access in tight spaces.
Place the forward/reverse button 
position or remove battery pack before changing accessories.
To install an accessory (Fig F), push accessory to fully insert
into chuck 
 6 
. The chuck collar 
to lock accessory in place.
To remove an accessory (Fig G), pull the chuck collar away
from the front of the tool. Remove the accessory and release
 8 
the collar.
Usage
Your impact tool generates the following maximum torque:
Cat #
DCF809

CAUTION: Ensure fastener and/or system will withstand
the level of torque generated by the tool. Excessive torque
may cause breakage and possible personal injury.
1. Place the accessory on the fastener head. Keep the tool
pointed straight at the fastener.
2. Press switch to start operation. Release the switch to stop
operation. Always check torque with a torque wrench, as
the fastening torque is affected by many factors including
the following:
Voltage: Low voltage, due to a nearly discharged
battery, will reduce fastening torque.
Accessory size: Failure to use the correct accessory
size will cause a reduction in fastening torque.
Bolt Size: Larger bolt diameters generally
require higher fastening torque. Fastening torque
will also vary according to length, grade, and
torque coefficient.
Bolt: Ensure that all threads are free of rust and other
debris to allow proper fastening torque.
Material: The type of material and surface finish of
the material will affect fastening torque.
Fastening Time: Longer fasten ing time results in
increased fastening torque. Using a longer fastening
time than recom mended could cause the fasteners to
be overstressed, stripped or damaged.
MAINTENANCE
Your D
WALT power tool has been designed to operate
e
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regular cleaning.

WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect battery pack
before making any adjustments or removing/
installing attachments or accessories. An accidental
start-up can cause injury.
The charger and battery pack are not serviceable.
in the locked off (centre)
 4 
 5 
does not need to be pulled up
Nm
Ft.-Lbs.
190
142
In.-Lbs
1700

Publicité

loading

Ce manuel est également adapté pour:

Xr dcf809nXr dcf809d2tDcf809