Figure 14 – Two stage gas valve
Figure 15 – Adjustment screw
Table 6 – Maximum capacity of pipe Cu.ft./Hr for pipe length ft (m)
Nominal Iron pipe size in. (mm)
1/2 (13)
3/4(19)
1 (25)
1-1/4 (32)
1-1/2 (39)
Gas Pressure in w.c. (psig)
Internal dia. in. (mm)
10 (3.0)
0.622 (158)
0.824 (20.9)
1.049 (26.6)
1.380 (35.0)
1.610 (40.9)
16
Table 4 – Inlet gas pressure
Maximum
Minimum
Table 5 – Outlet gas pressure
Gas Pressure in w.c.
High fire (100%)
Low fire (70%)
Figure 16 – Typical gas pipe arrangement
20 (6.0)
30 (9.1)
175
120
97
360
250
200
680
465
375
1400
950
770
2100
1460
1180
Natural gas
Propane
10.5 (0.38)
13.0 (0.47)
4.5 (0.16)
11.0 (0.40)
Natural Gas
Propane
3.0
8.6
1.55
5.0
40 (12.1)
50 (15.2)
82
73
170
151
320
285
660
580
990
900