Wireless input
F66
RIOED8WS
[T2]
Wireless input
F67
RIOPH8WS [T1]
Wireless input
F68
RIOPH8WS [T2]
Partial opening
F71
time
U1
Entering users
U2
Deleting users
U3
Deleting users
Decoding the
U4
radio-frequen-
cy code
A1
Motor type
Gate-swing
A3
calibration
Resetting
A4
parameters
Maneuver
A5
count
Adjusting the
A6
motor torque
H1
Version
Wireless safety device (RIOED8WS) associated to a function of choice among those
available: P0 = TOTAL STOP, P7 = reopening during closing, P8 = reclosing during
opening.
For programming, see the instructions that come with the accessory.
 This function only appears if the RIOCN8WS card is plugged into the control board.
OFF = Deactivated (default) / P0 / P7 / P8
RIOPH8WS is associated to any function chosen among those available: P1 = reopening
during closing; P2 = reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
 This function only appears if the RIOCN8WS card is plugged into the control board.
OFF = Deactivated / P1 (default) / P2 marked areas / P3 / P4
RIOPH8WS is associated to any function chosen among those available: P1 = reopening
during closing; P2 = reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
 This function only appears if the RIOCN8WS card is plugged into the control board.
OFF = Deactivated / P1 (default) / P2 marked areas / P3 / P4
After an opening command from the button connected to 2-3P, the gate opens for an
adjustable time of between five seconds and 40 seconds.
 This function only appears if the Encoder function is deactivated.
5 = 5 seconds /... / 40 = 40 seconds
Entering up to 250 users and associating to each one a function of choice among those
included. This must be done via transmitter or other control device (see "ENTERING
USERS WITH ASSOCIATED COMMAND paragraph).
1 = Step-step command (open-close) / 2 = Sequential command (open-stop-close-
stop) / 3 = Open only command / 4 = partial command
Deleting a single user
OFF = Deactivated / ON = Activated
Deleting all users.
0 = Deactivated (default) / 1 = Delete
Select the type of transmitter radio coding that you wish to save on the control board.
⚠ When you select a radio coding, all saved transmitter are automatically deleted.
 TWIN's coding lets you save multiple users with the same key (Key block).
1 = all series ( default) / 2 = only Rolling Code series /3 = only TWIN series
To set the gearmotor depending on the gate's weight.
1 = 400 kg /2 = 600 kg / 3 = 800 kg / 4 = 1000 kg
Automatic calibration of the gate-leaf swing (see the CALIBRATING SWING paragraph).
OFF = Deactivated / ON = Activated
Caution! The default settings are restored and the travel calibration deleted.
OFF = Deactivated / ON = Activated
For viewing the number of maneuvers completed or for deleting them (001 = 100
maneuvers; 010 = 1000 maneuvers; maneuvers; 999 = 99900 maneuvers; CSI =
maintenance job).
For adjusting the motor torque from 1 (minimum) to 5 (maximum).
1 / 2 / 3 / 4 / 5
View the firmware version.