Télécharger Imprimer la page

CAME BXV Tall Serie Manuel D'installation page 50

Publicité

Les langues disponibles

Les langues disponibles

Connecting the safety devices (i.e. the safety test)
At each opening and closing command, the control board checks the efficacy of the safety devices (such as,
photocells).
Any malfunction inhibits any command and is signaled on display E4.
Enable function F 5 in programming.
1 2 3P 7
-
+
-
+
RX
10 2 TX C
NC
DELTA-S
RIO WIRELESS DEVICES
Plug the RIOCN8WS card into its corresponding connector on the control board.
Set the function to be associated to the wireless device (F65, F66, F67 e F68).
Configure the RIOED8WS, RIOPH8WS and RIOLX8WS wireless accessories by following the indications shown in
the folder enclosed with each accessory.
 If the devices are not configured with the RIOCN8WS card, the display will read out E18.
⚠ If there are any radio-frequency disturbances to the system, the wireless system will inhibit the normal operation
of the operator, and this error will show up on the display as E17.
CONNECTION FOR PAIRED OPERATION AND FOR CRP (CAME REMOTE PROTOCOL)
See the PAIRED CONNECTION WITH SINGLE
CONTROL chapter.
A B GND
1 2 3 4
UTP CAT 5
10 TS 2 CX CY
FC FA F
-
TX
TX 2
TX 2
DIR
RIOCN8WS
1
2
3
4
+ E -
1 2 3P 7
M N
RX
+ - NO C NC
RIOED8WS
RIOPH8WS
10 TS 2 CX CY
FC FA F
TX
+
TX 2
-
DELTA
RIOLX8WS
Fit the RSE card.
+

Publicité

loading

Ce manuel est également adapté pour:

Bxv04agtBxv06agtBxv08agtBxv10agt