SAFETY DEVICES
Photocells
Configure contact CX or CY (NC), safety input for photocells.
See CX input functions (Function F2) or CY (Function F3) in:
- C1 reopening during closing. When the gate is closing, opening the contact triggers the inversion of movement
until the gate is fully open again;
- C2 close back up during opening. When the gate is opening, opening the contact triggers the inversion of
movement until the gate is completely closed.
- C3 partial stop. Stopping of the gate, if it is moving, with consequent automatic closing (if the automatic closing
function has been entered);
- C4 obstruction wait. Stopping of the gate, if it is moving, which resumes movement once the obstruction is
removed.
 If contacts CX and CY are not used they should be deactivated during programming.
1 2 3P 7
-
+
RX
10 2 TX C
NC
DELTA-S
Sensitive Safety Edges
Configure contact CX or CY (NC), safety input for sensitive safety-edges.
See CX input functions (Function F2) or CY (Function F3) in:
- C7 reopening during closing. When the gate is closing, opening the contact triggers the inversion of movement
until the gate is fully open again;
- C8 reclosing during opening. When the gate is opening, opening the contact triggers the inversion of movement
until the gate is fully closed.
 If contacts CX and CY are not used they should be deactivated during programming.
1 2 3P 7
10 TS 2 CX CY
DFWN
10 TS 2 CX CY
FC FA F
TX 2
TX 2
DIR
+ E -
FC FA F
24 0
10 11 E
+ E -
M N
-
TX
RX
+ - NO C
5
M N
L
DFWN with control card for the
10 TS 2 CX CY
1 2 3P 7
NC
DELTA
10 TS 2 CX CY
1 2 3P 7
E1 EX W
N
DFI connections
+
FC FA F
L
N
-
TX
+
TX 2
-
FC FA F
E1 E
L
N
24V

Publicité

loading

Ce manuel est également adapté pour:

Bxv04agtBxv06agtBxv08agtBxv10agt